Media: | Ammonia, Fluorine,Propane,Propylene,etc |
---|---|
Temperature: | -50 to +150 |
Actuator: | Manual |
Material: | Carbon Steel |
Structure: | Y-Global Globe Valve |
Application: | Refrigeration Valve |
Customization: |
---|
Suppliers with verified business licenses
Technical parameters:
Nominal pressure: 2.8MPa Applicable temperature:-50ºC~+150ºC
Test pressure: 4.2MPa Applicable medium:ammonia,fluorine,etc.
Characteristics:
- The Pilots ACVC are used as downstream pressure regulators, mounted directly over main valves AM1 or AM3. They can be also mounted on a housing valve CVH in an external line to control one or more AM valves.
- The Pilots ACVC working by a range of pressure regulation of 0.5 Bars to 7 Bars.
- Turning the regulating spindle clockwise to increase the opening pressure of the pilot,(For exmple the suction pressure) and it decreases when we turn the spindle anticlockwise.
- ACVC combines AM main valve to regulate maximum suction pressure,such as crankcase pressure of compressor.
- The reference pressure must be connected to the low pressure side of the system.
Pilots Style | Max Working pressure(bar) | KV(m^3/h) | Tem Range | Pressure Range |
ACVC | 28 | 0.4 | -50/+120 | 0.5-7 |
Pilots valve seat | L | L1 | H | D | d1 | B |
ACVH | 70 | 50 | 35 | 23.5 | NPT3/8 | M24x1.5 |