Evaporative Condenser Efficient Heat Exchange Equipment

Condensation Forms: Water-Cooled
Type: Steam Condenser
Material: Stainless Steel
Application Field: Cold Storage
Condition: New
Transport Package: Upper and Lower Box Bodies
Customization:
Gold Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
  • Overview
  • Product Description
  • Product Parameters
  • Company Profile
Overview

Basic Info.

Model NO.
MKS
Trademark
Qianchuan
Origin
China
HS Code
8481804090
Production Capacity
50000PC/Year

Product Description

Product Description

MKS series evaporative condenser is a kind of highefficient heat exchange equipment renovated and developed on the basis ofabsorbing the most advanced heat-exchangeTechnology abroad.

MKS series evaporative condenser uses water and air as cooling agent.The cooling agent exchanges the heat with hightemperature gaseous refnigerant agent and hence the refnigerant agent becomes liquid.Inside it has a water distribution system,condensing coils,wet deck,dehydrator and so on.Outside it has a water circulating pump,an electronic water curing device and apropeller fan on the top of condensing coil.The propeller fan strengthens the flow of the air and causes negative pressure inside.When the condenser runs,the cooling water is pumped and then sprayed by water distribution system on the surface of condensingcoil equably to form a thin layer of water film.The high-temperature steam of refrigera nt agent enters from the top of condensing coiland then the cooled liquid refrigerant agent is discharged from the bottom of the condensing coil.During this process,high temperature refrigerant agent exchanges the heat with the water and air outside the coil and increases the effect of heat exchange with thehelp of wind.After absorbing the heat of refrigerant agent,some water turns into steam and is discharged by prop eller fan.Meanwhile,the moisture in the air is collected by dehydrator to basin,and the Ungasified cooling water flows in to wet deck and its heat is takenaway by the airflow.The cooled water converges in the basin to be used circularly by the pump later.In addition,there is a ball cock inthe basin.When the water is consumed to a certain point,the ball cock will automatically open to replenish the cooling Water.
Evaporative Condenser Efficient Heat Exchange Equipment

Evaporative Condenser Efficient Heat Exchange Equipment

Product Parameters

MKS series products adopt the technology ofthe combination of coil and stuffing to avoid thedry spot and dirty forming on the coils.So theperformance of heat exchange is high effective.Because of the same direction of airflow and water flow, the spray water can cover the surface of coils furthest and keeps the surface
completely wet. Compared with the reverse direction of water flow and airflow, this structure can reduces greatly the dry spot and dirty.

Evaporative Condenser Efficient Heat Exchange EquipmentSingle  cell  MKS-145~430 Boundary Dimensions and Technical Parameters
Evaporative Condenser Efficient Heat Exchange Equipment

Tpye

Heat  refection
under

Nominal operating
mode

Propeller lan

Water  circulating
pump
NH2
Filing rate

Weight

Amount

Blowing
  rate

Power
 
Discharge
   rate

Power

Transportation

Operating
KW   m/h KW m/h KW Kg Kg Kg
MKS-145
MKS-160
MKS-180
MKS-200
MKS-220
MKS-240
MKS-260
MKS-280
MKS-300
MKS-340
MKS-380
MKS-400
MKS-430
145
160
180
200
220
240
260
280
300
340
380
400
430
  1x18000
1x22000
1x28000
1x22000
1x28000
1x35000
1x28000
1x35000
1x40000
1x35000
1x40000
1×45000
1×65000
0.75
1.1
1.5
1.1
1.5
2.2
1.5
2.2
3.0
2.2
3.0
4.0
4.0
28
28
28
28
28
28
46
46
46
46
46
46
46
0.75
0.75
0.75
0.75
0.75
0.75
1.1
1.1
1.1
1.1
1.1
1.1
1.1
17
17
17
25

25
34
34
34
39
39
39
41
1660
1665
1700
1860
1890
1920
2030
2045
2060
2280
2300
2330
2490
2685
2690
2700
2880
2870
3050
2890
3050
3060
3660
3670
3680
3830

Tpye
Dimension
Compensate
on
water pipe

Aischarge
pipe

Overflow
pipe

Air inlet
pipe

  Water
   outle
  pipe
A B C D E F G H J
mm mm mm mm mm mm mm mm mm A B C D E
MKS-145
MKS-160
MKS-180
MKS-200
MKS-220
MKS-240
MKS-260
MKS-280
MKS-300
MKS-340
MKS-380
MKS-400
MKS-430
1830
1830
1830
1830
1830
1830
1830
1830
1830
1830
1830
1830
1930
2210
2210
2210
2210
2210
2210
2210
2410
2410
2710
2710
2710
3010
1470
1470
1470
1470
1470
1470
1470
1470
1470
1470
1470
1470
1475
1000
000
000
1000
1000
1000
1000
1000
1000
1000
1000
1000
000
440
440
440
440
440
440
440
440
440
440
440
440
440
376
376
376
614
614
614
614
614
614
614
614
614
614
2000
2000
2000
1760
1760
1760
1760
1760
1760
1760
1760
1760
1760
2915
2915
2915
2915
2915
2915
2915
2915
2915
2915
2915
2915
2915
280
280
280
280
280
280
280
280
280
280
280
280
280
DN25
DN25
DN25
DN25
DN25
DN25
DN25
DN25
DN25
DN25
DN25
DN25
DN25
DN65
DN65
DN65
DN65
DN65
DN65
DN65
DN65
DN65
DN65
DN65
DN65
DN65
DN65
DN65
DN65
DN65
DN65
DN65
DN65
DN65
DN65
DN65
DN65
DN65
DN65
DN80
DN80
DN80
DN80
DN80
DN80
DN80
DN80
DN80
DN80
DN80
DN80
DN80
DN50
DN50
DN50
DN50
DN50
DN50
DN50
DN50
DN50
DN50
DN50
DN50
DN50
 

NOTES APPLICABLE ON ALL MODELS

1.The standard right hand arrangement as shown has the air inlet side onThe right when facing the refrigerant connection end.Left hand can beFumished by spevial order.Water and refrigerant connections and pumpPiping.Are always locaied on the same end of the unit

2.Standard refrigerant inlet and outlet connections are beveled for

welding And have a diameter DN100.Other connection sizcs are availableon special order.

3.Rerfrigerant charge listed is R717 operating.To determine operatingcharge for R22.Multiply charge by 1.93 and for R134A by 1.98.

4.Operating weight shown in the tables is based on total unit weight.Weight of refrigerant operating charge and basin filled to overflow level

Company Profile

Our products are widely applied to electricity generating stations, metallurgy, petrochemical industry,motor-dom, textile,hotels, food industry,tobacco industry, pharmaceuticals industry, electronic industry and papermaking.

The Company R&D base is located in Yixing City,Jiangsu Province,covers an area of up to30060m²,the production workshop more than 19000 square.Department of Jiangsu Province,the largest production base of the whole refrigeration products.It has a series of advancedCNC machine tool equipment to ensure product quality is excellent,the establishment of thesystem of production management standardization and quality assurance,and skilled front-line production workers,is to ensure the high quality of the products,the companyproduction equipment,large equipment,shear,punching,folding milling,car and so on 22,the annual production 350000 tons of cooling tower,a single flow from 5m³/h to 800m³/h ason 1000 kinds of specifications.

The company has a professional customer service team,providing guidance,equipmentinstallation debugging and repair and maintenance services for customers,to provide a solidguarantee for the products are applied in various industries,and won the customers trustand praise!

Evaporative Condenser Efficient Heat Exchange Equipment  

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now