DESCRIPTION
The Pilots ACVP-L are used as constant pressure regulators, mounted directly over main valves AM1 or AM3.They can be also mounted on a housing valve EC type CVH in an external line to control one or more AM or RAK valves.
The Pilots ACVP-L & ACVP-M both working in lower pressure, but in different range of regulation:
ACVP-L: 0 Bars to l0 Bars
ACVP-M: -0.65 Bars to 7 Bars
Turning the regulating spindle clockwise increases the opening pressure of the pilot, ( thus the evaporating pressure and temperature),and they decrease when we turn the spindle anticlockwise
Pilot valves are used to keep the inlet pressure of AM main valve constant. The low-pressure ACVP-L should avoid vibration.
When ACVP is installed on the CVH seat, it can be used as either a separate constant pressure valve or a safety pressure valve.
PARAMETER
Type |
kv([m3/h]) Mex warking resure |
(bar) Temperature Pressure |
ACVP-L |
17 |
0.4 |
-50C+120 |
0-10 |
ACVP-M |
17 |
0.4 |
-50C+120 |
-0.65-7 |